<title> <META NAME="description" CONTENT="JBS Instruments specializes in stream flow measurement devices like the AquaCalc that are used in the field of hydrology."> <META NAME="keywords" CONTENT="jbs instruments aquacalc aquacount stream flow measurement water discharge current meter hydrology usgs"> </title>
Downloads - AquaCalc Pro
[JBS] [Instruments] [Downloads] [Pro Downloads]

AquaCalc Pro Instruction ManualDownload AquaCalc Pro Manual

 

Click here to download an Adobe Acrobat version of the AquaCalc Pro Manual. (2 Mb) You may also contact JBS and request a printed version of the manual.

 


AquaCalc Pro Firmware Updates

The firmware in the AquaCalc Pro can be updated by the user. (Which firmware do I have?) Each firmware update includes all of the previous version fixes and improvements. You will need to perform the following steps:

  1. Copy all data from the AquaCalc Pro to your computer using the DataLink program.

    WARNING: All Sections and observations in the AquaCalc Pro may be lost when updating the firmware!
     
  2. Download the AquaCalc Pro Firmware Updater version 1.2.1 setup program from this site by clicking here.
    Filename: AQPU_121.exe. - Size 2.00 Mb
  3. Save the Updater Setup to your computer and then double-click it to install the Updater program on your computer.
  4. Connect the AquaCalc Pro to your computer using the data communications cable provided with your Pro.
  5. Run the AquaCalc Pro Firmware Updater by selecting AquaCalc Pro Firmware Updater from the Windows Start Menu. Follow the on-screen directions in the Updater.
  6. After your AquaCalc Pro firmware has been updated, you may remove the Updater software from your computer using the Windows Add/Remove Software function found in the Control Panel.

Note: Older AquaCalc 5000s, both the Basic and the Advanced, cannot use this update. To update your older AquaCalc 5000s click here.


Firmware updates
version description.

Version 1.2.1 -- April 28, 2006 -- Download

We recommend this update for users who work in metric units with current meters rated in English/SAE units (feet per second).

1) Fixed problems with metric conversions when using English / SAE rated current meters and measuring in metric units.

 

Version 1.1.4 -- December 16, 2005 -- Download

Released 11/17/2005

1) “LEW No” in header output changed to read "LEW"
 
2) Incorrect hanger bar length when using metric fixed: Now when System Preferences is set to "Metric" the values displayed for the hanger bar length are displayed in meters. In addition the bar length is adjusted into meters for the depth calculation.

3) Consistent navigation using keypad buttons: Navigation button functions changed to conform to the following:
 
 -Menu button: Takes the user to the Main Menu Screen. 

 -Measure button: Takes user to the Measure screen

 -Enter button: Moves up / back one level in hierarchy. (Exception: when the user presses ENTER from Section Setup or Vertical Setup Menus, they will be returned to the Measure Screen instead of to the Setup Screen.)

 -Esc button: Not used in navigating through menus or screens. Used to cancel the entry of numbers and text and restore previous values when performing data entry. Values are displayed as "reversed" text light on a dark background when this function is available.

4) Replaced "1 of 2" with “More” and “2 of 2” with “Back” in soft-key menus.
 

Version 1.1.3 -- January 23, 2004 -- Download

Note: The version Updater was released in September of 2004.

1) Display contrast setting in Preference Menu is saved. Once you have selected a display contrast level in the Preference menu it will be the default setting until changed.
2) Lighter contrast extended for hotter weather (Pro should be kept in shade). The range of contrast control in the graphic display has been changed and extended to accomodate the changes made by the manufacture of the display.
3) Preferences Keypad Beep saved.
4) Entries for the Staff Heigh and the Gage Height have been extended from 99 to 9999 ft.
5) Change of Output file to Output version 1.5 due to item 4


Version 1.1.2 -- Not Released

Version 1.1.1 -- June 16, 2003 --

1) Erase Obs now sets Horizontal Coefficient equal to 1.0.
2) If all sections full, the AQP will not enter the Measure Mode and signals the user to delete sections.
3) Section Data is saved every time a new vertical is created.
4) Addition of nonstandard meters

Version 1.1.0 -- Not Released

Version 1.0.9 -- April 4, 2003 -- Not Released

1. bug fixed: assembly date
2. bug fixed: Depth prompt when using cable
3. feature: Optical meter selections added to meter list

Version 1.0.8 -- January 30, 2003 --

Version AQP-1V1.0.8
Dated 01-30-03
Summary: This update fixes the rounding problem when summing the subsection values and calculating the totals.
Problem: When summing the subsection values a rounding error was occuring with the totals.
Status: Rounding modified to meet the letter provided by Kirk Thibedoux of the USGS-HIF

Version 1.0.7 -- November 22, 2002 --

Version: "AQP-1V1.0.7";
File Version: "V1.4";
Date 11-22-02

Firmware mods
-------------------------------------------------------------------
(1) Low battery check disabled during power-down
(2) Enter key to return from "Meas > Setup" menu
(3) Enter key to return from "Meas > Setup > Vertical Setup" menu
(4) Elapsed time for measuring entire Section calculated
(5) Insert Vertical moves to Inserted Vertical

File download mods (File Version: "V1.4")
-------------------------------------------------------------------
(1) Elapsed time for measuring entire Section x.xx hours added to header data (NA if dates aren’t equal)
(2) vertical area increased to 100th

Version 1.0.6 - (Not Released)

AquaCalc Pro 1.0.6
Date: 10-11-02

Additions to the AquaCalc Pro Firmware in Version AQP-1.0.6

1. Horizontal angle calculation in the download has been corrected. In the downloaded file the output displayed both the horizontal angle "HA" and the cosine coefficient (HC) of the horizontal angle "HC:VF" were incorectly displayed. The horizontal angle coefficient was always correctly displayed and correctly adjusted the velocity. However, the horizontal angle HA was not correctly represented in the output creating confusion.

2. Observation "Time Stamps" are now included on all observations including walls and edge of water.

3. Additional entry in the sounding weight list "User 0.00", allows the user to use any sounding weight without the hanger bar adjustment being automatically added to the depth. The value of the sounding weight on the output is a blank "_____".

4. Measurement syncronization problem has been enhanced.

5. Meter setup table protected from accidently editing an existing nonstandard meter.

Version 1.0.5

  • >modifications:
  • Fixed Auto power-down lock-up
  • Fixed Swap Observation Data Command from lock-up
  • >Features added:
  • Measure screen includes "Prev.Vert. %Q: x.xx on display line 14
  •   Allows user view %Q of previous vertical.

Version 1.0.4

Not released

  • >modifications:
  • User entry of staff gage height
  • Return to Section Setup Menu after Meter Select key is pressed

Version 1.0.3

  • >Features added:
  • Meter setup menu for 10 meters
  • Swap Observation
  • >Modifications:
  • Date and Timestamps changed per request
  • Text entries are now left justified
  • >Output additions:
  • Meter Revs/Pulses ratio added
  • Meter type added
  • Meter std added
  • HEX byte 1A added to end of upload file
  • 1. Measure time from 0-250 seconds properly displayed
  • 2. Error beep when invalid Meas. Options are pressed
  • 1) FIX: PAA max depth set to 0.00

Version 1.0.2

  • Addition of meter edit screen
  • Changed:
    • Display Rev and Time
    • Added Move Observation
    • Fixed Escape Keys
    • Left Justify Text Entry
    • Fixed rounding problem
    • Redid Escape keys
    • Added Quality to the output screen with menu item

Version 1.0.1

  • Addition of meter edit screen
  • Changed:
    • Display Rev and Time
    • Added Move Observation
    • Fixed Escape Keys
    • Left Justify Text Entry
    • Fixed rounding problem

Version 1.0.0